ACB uye MCCB
Summary
GPU1/2/3 Series smart universal air circuit breaker yakagadzirirwa zvigadzirwa zvakagadziridzwa nesu, rated voltage ye AC 50/60Hz, 480V(690V), yakayerwa ikozvino 200A~6300A, inonyanya kushandiswa kugovera simba nekudzivirira maseketi ekugovera magetsi. network, kudzivirira magetsi uye kukuvara kwemidziyo yemagetsi kubva pakukanganisa kwekuremerwa kwakanyanya, pfupi-dunhu, kukanganisa kwepasi, nezvimwe .. Iyo ine yakakwirira chaiyo yakasarudzika yekudzivirira uye inovandudza kuvimbika kwesimba rekupa.Breaker zvakare ine basa rekuzviparadzanisa nevamwe, rinoenderana nechiyero cheGB 14048.2, IEC 60947-2.
Features
1. Compact structure
2. Hapana flashover chinhambwe Kuchengetedza kwakanyanya
3. Kukwanisa kwepamusoro kweOn-Off
4. Smart mhando pamusoro-ikozvino rwendo dziviriro, nekukurukurirana interface, Inogona kudzorwa nekombuta cluster, akaziva kure kure.
5. Ratidza basa reammeter, voltmeter
6. Kukwira nekudzika kunouya hakuzokanganisa kuita kwechigadzirwa
Model
GPU3 | Universal air circuit breaker |
1600 | Shield furemu ikozvino |
4 | 3 3-chikamu kwete chiratidzo 4 4-Chikamu |
3M mhando smart controller | Smart controller 2M mhando: Digital chubhu kuratidza, bhatani kugadzirisa, 3 chikamu chine ivhu rekudzivirira kukanganisa basa 3M mhando: LCD kuratidza, bhatani kugadzirisa, 3 chikamu chine pasi pekudzivirira kukanganisa basa 3H mhando: LCD kuratidza, bhatani kugadzirisa uye yekutaurirana, 3 chikamu ne earthing kukanganisa kuchengetedza basa. |
Mounting nzira | Dhirowa-kunze mhando Fixed type |
Kubatanidza nzira | Yakachinjika wiring vertical wiring Plate-rear front wiring |
Zvishandiso sarudzo | Under-voltage tripper Mechanical interlock: 2 seti kana 3 seti inopwanya mune yakatwasuka lever yakavharirwa 2 seti yekutyora yakachinjika kana yakatwasuka yakavharwa netambo yesimbi “Vhura” kiya chinzvimbo (kiyi kiyi) Dhirowa-kunze 3 chinzvimbo switch Kunze kwekubatanidza N phase transformer |
Mu=630 | Yakatemerwa ikozvino (A) |
Cherechedza:
1. Smart controller iM mhando;Wekubatsira switch: 4 mapoka 'anobatika, Yekubatanidza nzira iri mukati yakachinjika.
2. Smart controller, shunt release device, close electromagnetic, motor drive mechanism uye under-voltage tripper ichataurwa kukosha kwevoltage paunohodha.
Technical Selection Tafura
Type | Rated kushanda voltage Ue (V) | Rated insulating voltage Ui (V) | Rated impulse inomira voltage Uimp (V) | Shield frame ikozvino Inm (A) | Rated current Ini (A) | Nhamba yechikamu |
GPU1-1250 | AC400 AC690 | AC690, AC1000 | 12000 | 1250 | 200, 400,630, 800,1000, 1250 | 3, 4 |
GPU1-2000 | 2000 | 630, 800, 1000, 1250, 1600, 2000 | ||||
GPU1-3200 | 3200 | 2000, 2500, 3600, 4000 | ||||
GPU1-6300 | 6300 | 4000, 5000, 6300 |
Short-circuit breaking capacity | Yakatemerwa nguva pfupi inomira ikozvino Icw (kA)/1s | Kushanda kwekushanda | |||||
Yakatemerwa max ipfupi-sekete yekutyora simba Icu (kA) | Yakatemerwa kumhanya-pfupi-sekete yekutyora simba Ics (kA) | Mechanical hupenyu (nguva) | Upenyu hwemagetsi (nguva) | ||||
400V | 690V | 400V | 690V | 400V | 690V | ||
50 | 42 | 42 | 15000 | 6000 | |||
80 | 50 | 50 | 40 | 50 | 40 | 15000 | 10000 |
100 | 65 | 80 | 50 | 80 | 50 | 12000 | 8000(5000) |
120 | 75 | 100 | 65 | 100 | 65 | 3000 | 1000 |
GPM11 Molded Case Circuit Breaker
GPM11Z Smart Molded Case Circuit Breaker
Pfupiso yeGPM11/GPM11Z
GPM11 akateedzana akaumbwa kesi circuit breaker inokodzera AC 50/ 60Hz yakayerwa kushanda voltage 400V/630V, yakayerwa ikozvino kusvika ku800A yemagetsi ekugovera network yekugovera simba nekudzivirira maseketi, magetsi uye midziyo yemagetsi pakuremerwa, pasi-voltage uye. mapfupi edunhu njodzi, inovandudza kuvimbika kwesimba rekushandisa pasi pemamiriro ekushandisa akajairika ayo asingawanzo kutanga seasingawanzo mutsara kutendeuka uye mota.Uye nebasa rekuzviparadzanisa nevamwe zvakare.Inosangana neyakajairwa GB/T 14048.2 uye IEC 60947-2.
Model
GPM11GPM11Z | Molded Case Circuit BreakerSmart Molded Case Circuit Breaker |
100 | Shield furemu ikozvino |
H | Short-circuit breaking capacity:N: Normal type S: Standard typeH: High-breaking type |
P | Nzira yekushanda: Kushanda kwemotokari: Protate mubato unoshanda: ZDirect kushanda (hapana kodhi) |
2 | Kudzivirirwa chimiro Sarudzo: kuchengetedzwa kwekugovera: hapana kodhiMotor dziviriro: 2 |
4 | Phase number2 : two phase3 : three phases4 : zvikamu zvina |
208 | Rwendo nzira uye yemukati accessories kodhi |
Mu=100 | Yakatemerwa ikozvino (A) |
B | 4 Phase breaker N phase ine 4 mhando dzakasiyana dzakatarwa seA, B, C, DA: N chikamu hachizoisa yazvino tripper, uye N yakabatana nguva dzose, isingashandiswe nemamwe 3 phases. chikamu chisina kushanda nemamwe 3 phases.C: N chikamu chakaiswa chetatu chazvino, uye N chikamu chinoshanda nezvimwe zvikamu zvitatu.D: N chikamu chakaiswa chetatu chazvino, uye N chikamu chakabatana nguva dzose, Haishandiswe nezvimwe zvikamu zvitatu. |
Q | Wiring nzira:Kumberi kweplate wiring: QRear yeplate wiring: HPlug-in type wiring: R |
Cherechedza: 1. Wiring nzira: shure kweplate wiring (400, 630's 4P isina iyo);plug-in mhando wiring (4P isina iyo)
2. Zvishandiso zvemukati zvakaiswa murutivi rworuboshwe rwebreaker.
Tafura yekusarudza tekinoroji yeGPM11Z MCCB
Type | Rated kushanda voltage Ue (V) | Rated insulating voltage Ui (V) | Rated impulse kutsungirira voltage Uimp (V) | Shield frame ikozvino Inm (A) | Rated current Ini (A) | Nhamba yechikamu | Short-circuit breaking capacity | Yakatemerwa nguva pfupi inomira neIcw yazvino (kA) 1s | Kushanda kwekushanda | ||
Yakatemerwa max ipfupi-sekete yekutyora simba Icu (kA) | Yakatemerwa kumhanya-pfupi-sekete yekutyora simba Ics (kA) | Mechanical hupenyu (nguva) | Upenyu hweMagetsi (nguva) | ||||||||
GPM11Z-100 | AC400 | AC690 | AC8000 | 100 | 32, 100 | 3,4 | 65 | 50 | 1 | 20000 | 8000 |
GPM11Z-225 | 225 | 225 | 65 | 50 | 2.5 | 20000 | 8000 | ||||
GPM11Z-400 | 400 | 400 | 65 | 50 | 5 | 15000 | 7000 | ||||
GPM11Z-630 | 630 | 630 | 65 | 50 | 8 | 10000 | 7000 |
Tafura yekusarudza tekinoroji yeGPM11 MCCB
Type | Rated kushanda voltage Ue | Rated insulating voltage Ui | Rated impulse inomira voltage Uimp | Frame kirasi yakayerwa ikozvino Inm A | Yakatemerwa ikozvino mu (A) | Nhamba yechikamu | Yakatemerwa max pfupi-circuit breaking capacity code | Rated max short -circuit breaking capacity | Yakatemerwa kumhanya-pfupi-sekete yekutyora simba Ics (kA) | Trip mudziyo mhando | Operation performance (nguva) | |
Rarama | Kwete-Kurarama | |||||||||||
GPM11- 63 | 400, 690 | 800, 1000 | 8 | 63 | 10, 16, 20, 25, 32, 40, 50, 63 | 3 | N | 10 | 5 | Kupisa electromagnetic | 3000 | 7000 |
3,4 | S | 25 | 18 | Kupisa electromagnetic | ||||||||
3,4 | H | 50 | 35 | Kupisa electromagnetic | ||||||||
GPM11-100 | 100 | 16, 20, 25, 32, 40, 50, 63, 80, 100 | 3 | N | 35 | 25 | Kupisa electromagnetic | 3000 | 7000 | |||
3,4 | S | 50 | 35 | Kupisa electromagnetic | ||||||||
3,4 | H | 65 | 50 | Kupisa electromagnetic | ||||||||
GPM11-160 | 160 | 100, 125, 140, 160 | 3 | N | 35 | 25 | Kupisa electromagnetic | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Kupisa electromagnetic | ||||||||
3,4 | H | 65 | 50 | Kupisa electromagnetic | ||||||||
GPM11- 225 | 225 | 100, 125, 140, 160, 180, 200, 225 | 3 | N | 35 | 25 | Kupisa electromagnetic | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Kupisa electromagnetic | ||||||||
3,4 | H | 65 | 50 | Kupisa electromagnetic | ||||||||
GPM11- 250 | 250 | 100, 125, 140, 160, 180, 200, 225, 250 | 3 | N | 35 | 25 | Kupisa electromagnetic | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Kupisa electromagnetic | ||||||||
3,4 | H | 65 | 50 | Kupisa electromagnetic | ||||||||
GPM11-400 | 400 | 225, 250, 315, 350, 400 | 3 | N | 35 | 25 | Kupisa electromagnetic | 1000 | 4000 | |||
3,4 | S | 50 | 35 | Kupisa electromagnetic | ||||||||
3,4 | H | 65 | 50 | Kupisa electromagnetic | ||||||||
GPM11- 630 | 630 | 400, 500, 630, 630, 700, 800 | 3 | N | 35 | 25 | Kupisa electromagnetic | 1000 | 4000 | |||
3,4 | S | 50 | 35 | Kupisa electromagnetic | ||||||||
3,4 | H | 65 | 50 | Kupisa electromagnetic | ||||||||
GPM11-800 | 800 | 630, 700, 800 | 3,4 | S | 50 | 35 | Kupisa electromagnetic | 1000 | 4000 | |||
3,4 | H | 65 | 50 | Kupisa electromagnetic |